Microseven® MSH-HSD080W-18X/23X/26X Network IP High Speed Dome
© 2002-2008 Microseven Systems, Inc. All Rights Reserved.
- 20 -
Appendix --- Lightening and Surge Protection
" This product uses TVS lightening-proof technology, which can protect the camera
from the damage by sudden lightening strike with power consumption no higher
than 1.5KW, and surge or other type of electronic pulses. However, if the camera is
installed outdoor, in condition of electric safety, certain measures are necessary
and described as follows:
" Signal cable must be kept 50m away from high voltage equipment or cable.
" Under the roof is recommended for outdoor wiring.
" In the open field, the cable must install within the grounded sealed steel pipe and buried
underground. Aerial wiring is strictly prohibited.
" In the area of frequent lightening and high sensitive voltage (such as high voltage
transformer substation), additional high power consumption lightening proof equipment
and lightening rod installation are necessary.
" The designing of grounding and lightening proof for outdoor equipment must meet the
standards of system anti-interference and electric safety, and connection with grounded
circuit conductor of high voltage electricity network is strictly prohibited. When the system
is grounded along, the ground resistor must be mo higher than 4 ohm, cross-section of the
ground wire must be less than 25m ㎡.
Comentarios a estos manuales